smartctl 7.4 2023-08-01 r5530 [OpenBSD 7.5 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Silicon Motion based SSDs
Device Model:     ADATA SU900
Serial Number:    --
LU WWN Device Id: 5 707c18 ...
Firmware Version: Q1018HD
User Capacity:    256,060,514,304 bytes [256 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
TRIM Command:     Available
Device is:        In smartctl database 7.3/5528
ATA Version is:   ACS-2 (minor revision not indicated)
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Sep  6 12:49:01 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.

General SMART Values:
Offline data collection status:  (0x02)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(    0) seconds.
Offline data collection
capabilities: 			 (0x71) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					No Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0002)	Does not save SMART data before
					entering power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (   2) minutes.
Conveyance self-test routine
recommended polling time: 	 (   1) minutes.
SCT capabilities: 	       (0x003d)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x0000   100   100   000    Old_age   Offline      -       0
  5 Reallocated_Sector_Ct   0x0000   100   100   000    Old_age   Offline      -       0
  9 Power_On_Hours          0x0000   100   100   000    Old_age   Offline      -       8843
 12 Power_Cycle_Count       0x0000   100   100   000    Old_age   Offline      -       3814
148 Total_SLC_Erase_Ct      0x0000   100   100   000    Old_age   Offline      -       2208
149 Max_SLC_Erase_Ct        0x0000   100   100   000    Old_age   Offline      -       192
150 Min_SLC_Erase_Ct        0x0000   100   100   000    Old_age   Offline      -       0
151 Average_SLC_Erase_Ct    0x0000   100   100   000    Old_age   Offline      -       138
159 DRAM_1_Bit_Error_Count  0x0000   100   100   000    Old_age   Offline      -       0
160 Uncorrectable_Error_Cnt 0x0000   100   100   000    Old_age   Offline      -       0
161 Valid_Spare_Block_Cnt   0x0000   100   100   000    Old_age   Offline      -       23
163 Initial_Bad_Block_Count 0x0000   100   100   000    Old_age   Offline      -       14
164 Total_Erase_Count       0x0000   100   100   000    Old_age   Offline      -       111874
165 Max_Erase_Count         0x0000   100   100   000    Old_age   Offline      -       264
166 Min_Erase_Count         0x0000   100   100   000    Old_age   Offline      -       164
167 Average_Erase_Count     0x0000   100   100   000    Old_age   Offline      -       216
168 Max_Erase_Count_of_Spec 0x0000   100   100   000    Old_age   Offline      -       3000
169 Remaining_Lifetime_Perc 0x0000   100   100   000    Old_age   Offline      -       93
177 Wear_Leveling_Count     0x0000   100   100   050    Old_age   Offline      -       357
181 Program_Fail_Cnt_Total  0x0000   100   100   000    Old_age   Offline      -       0
182 Erase_Fail_Count_Total  0x0000   100   100   000    Old_age   Offline      -       0
187 Reported_Uncorrect      0x0000   100   100   000    Old_age   Offline      -       0
192 Power-Off_Retract_Count 0x0000   100   100   000    Old_age   Offline      -       106
194 Temperature_Celsius     0x0000   100   100   000    Old_age   Offline      -       56
196 Reallocated_Event_Count 0x0000   100   100   016    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0000   100   100   050    Old_age   Offline      -       0
232 Available_Reservd_Space 0x0000   100   100   000    Old_age   Offline      -       100
241 Host_Writes_32MiB       0x0000   100   100   000    Old_age   Offline      -       449336
242 Host_Reads_32MiB        0x0000   100   100   000    Old_age   Offline      -       446611
245 TLC_Writes_32MiB        0x0000   100   100   000    Old_age   Offline      -       1789984

SMART Error Log Version: 1
Invalid Error Log index = 0x06 (valid range is from 1 to 5)
ATA Error Count: 0 (possibly also invalid)

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Offline             Completed without error       00%       139         -
# 2  Short offline       Completed without error       00%       225         -
# 3  Extended offline    Completed without error       00%        13         -
# 4  Short offline       Completed without error       00%        13         -
# 5  Offline             Completed without error       00%        97         -
# 6  Short offline       Completed without error       00%        85         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
    7        0    65535  Read_scanning was completed without error
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

The above only provides legacy SMART information - try 'smartctl -x' for more